2.1 Electronic characteristics
Punctuality +/- (displayed value’s rate(%) + the number of the digits) 23 +/-5 C°, if the humidity is lower than 75%.
DC Voltage
Measuring range Accuracy Resolution
200 mV 0,1 mV
2 V 1 mV
20 V 10 mV
200 V
+/- (0,5%+3)
100 mV
1000 V +/-(1,0%+5) 1 V
Input Impedance: 10 M
Overload Protection: 200 mV range : 250V DC/AC RMS
2-1000 V range : 1000 V DC/AC RMS
AC Voltage
Measuring range Accuracy Resolution
2 V 1 mV
20 V 10 mV
200 V
+/- (0,8%+5)
100 mV
750 V +/-(1,2%+5) 1 V
Input impedance: 2 V range:10 M
20-700 V range :10M
Overload protection: 1000V DC/AC RMS
Frequency range: 2-200 V range :40-400 Hz
750 V range :40-200 Hz
Shown value : average rate (in case of RMS sinus sign)